AIRMAN - AFTER COOLER pds-C series
- Reduce dirtiness due to water splash
- Reduce hotness and reduce the difficulties to hold.
- Reduce the rust damages to the air tools
- No air bubbles in paint.
- Remove freezing problems and able to move.
 
					 
					| Model | PDS185SC-3C5 | 
| Skft | |
| AIR COMPRESSOR | |
| Series | After-Cooler PDS series | 
| Type | Rotary Twin Screw, Single-Stage, Oil-cooled | 
| Free air delivery (m3/min) | 5.2 | 
| Rated operating pressure - Mpa [kgf/cm2] [psi] | 0.7[7.14] [102] | 
| Compressor capacity ( L ) | 15 | 
| Discharge Air Temperature | Atmospheric Temperature+20 | 
| Air outlet valve | 3/4"x3 | 
| ENGINE | |
| Make | YANMAR | 
| Model | 4TNV88-BXDHKSR | 
| Type | Direct-Injection | 
| Rated output ( kW (PS)/min'1 ) | 34.9 (47.5)/3,000 | 
| Engine oil capacity L | 7.4 | 
| Fuel tank capacity L | 90 | 
| Battery | 85D26RX1 | 
| DIMENSION AND WEIGHT | |
| Length X Width X Height ( mm ) | 1,850 X 1,130 X 1,270 | 
| Dry (Operating) weight ( kg ) | 800 (900) | 
| Tire Size | - | 
| Sound power level dB | 94 | 
| Sound pressure level dB[A] | 65 | 
| Designated emissions regulation | JPN Stage 3 | 
PERFORMANCE FEATURES
Adiabatic expansion within a high-load device such as a concrete breaker. rapidly cools compressed air, resulting in water droplets that can scatter from the breaker's exhaust or can freeze in some areas during winter. But since the integrated After-Cooler cools, condenses and eliminates moisture in the compressed air, the discharged air from PDS-C contains only a small amount of water. This functionality proves its true value in chipping and sandblasting operations.
Do you have the following experiences ?
- Dirty due to water splash.
- Too hot to hold.
- Rust damages the air tools.
- Air bubbles in paint.
- Frozen and unable to move.
All are caused by moisture within the compressed air !
As the After-cooler cools and condenses the moisture in the compressed air, the discharged air contains only a small amount of water.
Quantity of water generated from the discharged air.
 
							If the breaker is being used for 4 hours
1.8L X 3 bottles
Eliminate moisture from the discharged air.
 
							Moisture from the discharged air
Atmospheric pressure, 30°C, 70%RH 100 for a standard device
Moisture remove by 70%
Reduce the temperature of discharged air.
Discharged air temperature.
Atmospheric pressure. 30°C, 70%RH, Full load.
Discharged air temperature descend by 50%
 
	



 
				 
				 
 
											 
											 
		 
				 
		 
		 
		 
		 
		 
		 
		