AIRMAN - AFTER COOLER pds-C series
- Reduce dirtiness due to water splash
- Reduce hotness and reduce the difficulties to hold.
- Reduce the rust damages to the air tools
- No air bubbles in paint.
- Remove freezing problems and able to move.
 
					 
					| Model | PDS390SC-4C1 | 
| Trailer | |
| AIR COMPRESSOR | |
| Series | After-Cooler PDS series | 
| Type | Rotary Twin Screw, Single-Stage, Oil-cooled | 
| Free air delivery (m3/min) | 11 | 
| Rated operating pressure - Mpa [kgf/cm2] [psi] | 0.69 [7.0] [100] | 
| Compressor capacity ( L ) | 50 | 
| Discharge Air Temperature | Atmospheric Temperature+31 | 
| Air outlet valve | 3/4"X4, 2"X1 | 
| ENGINE | |
| Make | ISUZU | 
| Model | CI-4JJ1X | 
| Type | Direct-Injection,Turbo-Charged, Intercooled | 
| Rated output ( kW (PS)/min'1 ) | 84.4 (114.8)/2,200 | 
| Engine oil capacity L | 15 | 
| Fuel tank capacity L | 180 | 
| Battery | 85D26RX2 | 
| DIMENSION AND WEIGHT | |
| Length X Width X Height ( mm ) | 3,065 X 1,415 X 1,870 | 
| Dry (Operating) weight ( kg ) | 2,005(2,215) | 
| Tire Size | 175/80R13 97/95NX4W | 
| Sound power level dB | 98 | 
| Sound pressure level dB[A] | 70 | 
| Designated emissions regulation | JPN Stage 3 | 
PERFORMANCE FEATURES
Adiabatic expansion within a high-load device such as a concrete breaker. rapidly cools compressed air, resulting in water droplets that can scatter from the breaker's exhaust or can freeze in some areas during winter. But since the integrated After-Cooler cools, condenses and eliminates moisture in the compressed air, the discharged air from PDS-C contains only a small amount of water. This functionality proves its true value in chipping and sandblasting operations.
Do you have the following experiences ?
- Dirty due to water splash.
- Too hot to hold.
- Rust damages the air tools.
- Air bubbles in paint.
- Frozen and unable to move.
All are caused by moisture within the compressed air !
As the After-cooler cools and condenses the moisture in the compressed air, the discharged air contains only a small amount of water.
Quantity of water generated from the discharged air.
 
							If the breaker is being used for 4 hours
1.8L X 3 bottles
Eliminate moisture from the discharged air.
 
							Moisture from the discharged air
Atmospheric pressure, 30°C, 70%RH 100 for a standard device
Moisture remove by 70%
Reduce the temperature of discharged air.
Discharged air temperature.
Atmospheric pressure. 30°C, 70%RH, Full load.
Discharged air temperature descend by 50%
 
	



 
				 
				 
 
											 
											 
		 
				 
		 
		 
		 
		 
		 
		