AIRMAN - AFTER COOLER pds-C series
- Reduce dirtiness due to water splash
- Reduce hotness and reduce the difficulties to hold.
- Reduce the rust damages to the air tools
- No air bubbles in paint.
- Remove freezing problems and able to move.
Model | DIS-140LB-C |
BOX TYPE | |
AIR COMPRESSOR | |
After Cooler Type | |
Series | DIS Series |
Type | Rotary screw, single-stage compression, Oil cooled |
Delivered air pressure MPa | 0.70(102) |
Free air delivery m3/min (cfm) | 3.9(140) |
Lube Oil Capacity ( L ) | 15 |
Receiver Tank Capacity ( m3 ) | 0.23 |
Service Cock Size x Qty | 20AX3 |
ENGINE | |
Make | Yanmar |
Model | 3TNV88-BD |
Type | Direct injected |
No, of Cylnders-Bore x Stroke mm | 3-88X90 |
Displacement L | 1.642 |
Rated Output kW(PS) | 26.5(36) |
Rated Speed rpm | 3000 |
Fuel | Diesel Fuel (ASTM No.2 or equivalent) |
Fuel Tank Capacity L | 70 |
Fuel Consumption^2 L/h | 0 |
Lube Oil Capacity L | 6.7 |
Coolant Capacity L | 5.6 |
Battery x Quantity | 80D26RX1 |
DIMENSION AND WEIGHT | |
Length ( mm ) | 1700 <2760> |
Width ( mm ) | 875 <1380> |
Height ( mm ) | 1050 <1410> |
Dry Weight kg | 625 <735> |
Trailer. No. of Tires x Tire Size*' | 2x145R-10-6PR |
Sound Level 7mdB(A) | 67 |
PERFORMANCE FEATURES
Adiabatic expansion within a high-load device such as a concrete breaker. rapidly cools compressed air, resulting in water droplets that can scatter from the breaker's exhaust or can freeze in some areas during winter. But since the integrated After-Cooler cools, condenses and eliminates moisture in the compressed air, the discharged air from PDS-C contains only a small amount of water. This functionality proves its true value in chipping and sandblasting operations.
Do you have the following experiences ?
- Dirty due to water splash.
- Too hot to hold.
- Rust damages the air tools.
- Air bubbles in paint.
- Frozen and unable to move.
All are caused by moisture within the compressed air !
As the After-cooler cools and condenses the moisture in the compressed air, the discharged air contains only a small amount of water.
Quantity of water generated from the discharged air.
If the breaker is being used for 4 hours
1.8L X 3 bottles
Eliminate moisture from the discharged air.
Moisture from the discharged air
Atmospheric pressure, 30°C, 70%RH 100 for a standard device
Moisture remove by 70%
Reduce the temperature of discharged air.
Discharged air temperature.
Atmospheric pressure. 30°C, 70%RH, Full load.
Discharged air temperature descend by 50%